Journal of the American College of Radiology
Volume 6, Issue 11 , Pages 800-803, November 2009

Treatment Delays Using an Automated Afterloading Low-Dose-Rate Brachytherapy System

  • Colleen M. DesRosiers, PhD

      Affiliations

    • Department of Radiation Oncology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
    • Department of Obstetrics and Gynecology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
    • Corresponding Author InformationCorresponding author and reprints: Colleen DesRosiers, PhD, Melvin and Bren Simon Cancer Center, Department of Radiation Oncology, 535 Barnhill Drive, RT041, Indianapolis, IN 46202
  • ,
  • Eric Slessinger, MS

      Affiliations

    • Department of Radiation Oncology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
    • Department of Obstetrics and Gynecology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
  • ,
  • Jeanne Schilder, MD

      Affiliations

    • Department of Radiation Oncology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
    • Department of Obstetrics and Gynecology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
  • ,
  • Frederick Stehman, MD

      Affiliations

    • Department of Radiation Oncology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
    • Department of Obstetrics and Gynecology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
  • ,
  • Indra J. Das, PhD

      Affiliations

    • Department of Radiation Oncology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
    • Department of Obstetrics and Gynecology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
  • ,
  • Paul DesRosiers, MD

      Affiliations

    • US Oncology, Indianapolis, Indiana
  • ,
  • Higinia Cardenes, MD, PhD

      Affiliations

    • Department of Radiation Oncology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
    • Department of Obstetrics and Gynecology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
  • ,
  • Peter A.S. Johnstone, MD

      Affiliations

    • Department of Radiation Oncology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana
    • Department of Obstetrics and Gynecology, Indiana University School of Medicine/Melvin and Bren Simon Cancer Center, Indianapolis, Indiana

Purpose

Low-dose-rate (LDR) brachytherapy is an integral treatment modality in radiation oncology. Clinical efficacy is based on experience with manual source loading and continuous dose delivery. With remote afterloading technology, sources may be loaded and unloaded during the treatment course to prevent radiation exposure to nursing staff members and visitors. The aim of this study was to investigate treatment interruptions in terms of frequency and duration as well as extension of the overall treatment time period. The potential clinical impact of treatment interruptions was also considered.

Materials and Methods

The treatment records of 20 patients who underwent brachytherapy in the Indiana University Department of Radiation Oncology administered with a Selectron LDR remote afterloader were reviewed. Results were tabulated and analysis performed with respect to 1) the number of interruptions, 2) delay time, 3) delay time (Td) as a function of total implant time (T), 4) the time of day that each interruption occurred, and 5) the time in minutes of each individual interruption.

Results

The mean number of interruptions was 44.9 per patient, (range, 24-76), with a mean prescription implantation duration of 45.7 hours and a mean actual treatment time of 51.2 hours resulting in a mean interruption time of 6.4 minutes per treatment hour. The number of interruptions was standardized and divided by the number of prescribed dose in grays, translating to 1.2 to 3.7 interruptions per gray delivered, with a mean of 1.6, resulting in an average Td of 11.21% (range, 7.35%-17.12%).

Conclusion

Significant interruptions are frequent using remote afterloading LDR techniques, reducing the effective dose rate. Careful monitoring of such interruptions is warranted.

Key Words: Brachytherapy, dose-rate effect, remote afterloader

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 30.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1546-1440(09)00363-9

doi:10.1016/j.jacr.2009.07.013

Journal of the American College of Radiology
Volume 6, Issue 11 , Pages 800-803, November 2009